Infant Pediatric Adult Pulse Oximeter, SPO2 PC Software CE FDA, Heart Rate Monitor
Description
A pulse oximeter is a medical device that indirectly measures the oxygen saturation of a patient's blood
(as opposed to measuring oxygen saturation directly through a blood sample) and changes in blood volume in
the skin, producing a photoplethysmograph. It is often attached to a medical monitor so staff can see a patient's
oxygenation at all times. Portable battery-operated pulse oximeters are also available for home blood oxygen
monitoring.
Instructions
The principle of the CMS60D Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted by Capacity Pulse Scanning & Recording Technology, and the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger. The product is suitable for being used in families, hospitals, oxygen bars, community healthcare, and physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sports), etc.
Major Features
■Small in volume, light in weight, and convenient for carrying
■Operation of the product is simple, low power consumption
■Operation menu for the function setting
■SpO2 value display
■Pulse rate value display, bar graph display
■Pulse waveform display
■Screen brightness can be changed
■Pulse rate sound indication
■With review function
■With a clock function
■With measured data overruns limits and low-voltage alarm function
■Battery capacity indication
■Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage, and with alarm function
■With SpO2 value and pulse rate value of storage, the storage data can be uploaded to computers
■Real-time data can be transmitted to computers
■Connected with an external oximeter probe
Main performance
Display Mode:1.8" Color OLED display
Screen Resolution:160*128
SpO2 Measuring Range:0%~100%, (the resolution is 1%).
Accuracy:70%~100%:±2%, Below 70% unspecified.
PR Measuring Range:30bpm~250bpm, (the resolution is 1bpm)
Accuracy:±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when the pulse-filling ratio is 0.4%. The SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of the darkroom is less than ±1%.
Power Consumption: less than 100mA
Voltage: DC 2.6V~3.6V
Power Supply: Dry battery(2AA)
Battery working hours: The theoretical number is 44 hours.
Safety Type: Interior Battery, BF Type
Accessories
Sell in standard
■A user manual
■Adata line
■3 oximeter probe(Adult Paediatric & Neonatal Probe)
Physical Identity
Dimension:110(L) × 60(W) × 23(H) mm
Weight: About 180g